Ntesys contactors pdf files

The above selection curves show the contactor rating needed. Tesys iec contactors and starters steven engineering. Tesys contactors contactors and reversing contactors, model d instantaneous auxiliary contact blocks for use in normal operating environments in order to mount an lad8n on an lc1d40 to d95, la9d511 shims must be ordered separately, see page 223. Tesys f is a range of high current contactors from 115 a to a designed for ac3 applications and from 200 a to 2600 a for ac1 applications.

For control of appliances up to 63 a electric boilers, convection heaters, waterheaters, storage heaters and also lighting circuits. The schneider electric lc1d line of iec rated contactors are the most popular in the world with amp ranges from 9 to 150 amps and each contactor coming with 1 n. They can be used to interrupt high voltage, capacitive, resistive or inductive loads without. Acdc compatible coil, reversing contactors tesys d green. Tesys d iec contactor 12a vac coil on schneider electric. Selection guide tesys contactors tesys d contactors. Characteristics continued tesys contactors 0 tesys k contactors and reversing contactors auxiliary contact characteristics of contactors and instantaneous contact blocks number of auxiliary contacts on lcpk or lppk 3pole 1 on la1 k 2 or 4 rated operational voltage ue up to v 690 rated insulation voltage ui conforming to bs 5424 v 690.

This type of connection is not possible for blocks with dust and damp protected contacts. Browse our resource section and find the most useful tools and documents for all. References tesys contactors multiway control system. This allows you to simply and easily identify the level of fault. In this application, both a line and load isolation contactor is used only when the motor must be started by a 3rd acrosstheline dol starter that is run in parallel to the vfd. Characteristics tesys contactors tesys k contactors and. Dline contactors and overload relays are available in 11 contactor ratings for the usa market for inductive motor applications up to 150 fullload amps and resistive loads up to 200 a. For more information on machine safety applications using tesys d and tesys f contactors, refer to catalog mkted208051enus. Tesys d contactors and reversing contactors are available from 9 a to 150 a inductive motor, and from 20 a to 200 a resistive loads in 3pole and 4pole versions.

The dila and dilm7 to dilm38 contactors of the dilaxhir22 auxiliary contact are available specially for switching the smallest signals for electronic. Dec 28, 2018 a contactor connects or disconnects an electrical load. One that is quite common is in what is called a 3 contactor bypass. Control panel technical guide how to quickly design optimized. Schneider electric lc1d 3 pole contactors 9 to 150 amp. Across the line contactors a9 af1650 oss the 1 line 1. Feb 26, 2008 there are valid reasons for having contactors on the load side of a vfd however. Distant control of ac relays, contactors and starters bulletin no. Across the line contactors a9 af1650 a145 af1650 maximum ulcsa horsepower ratings according to ul508 and csa22. Choose contactors with nc auxiliary contacts to achieve electrical. Browse tesys d iec contactors in the schneider electric catalog including tesys d iec contactors screw,tesys d iec contactors spring,tesys d iec contactor ring tongue,tesys d iec contactors. Lc1d25bd tesys d contactor 3p3 no ac3 tesys d product or component type contactor device short name lc1d contactor application motor control resistive load utilisation category ac1 ac3 poles description 3p power pole contact composition 3 no ue rated operational voltage contactors range from 115 to 800 amp and offer side mounted auxiliaries and overload relays for complete motor. For more information on machine safety applications using tesys d and tesys f. Browse tesys d iec contactors in the schneider electric catalog including tesys d iec contactors screw, tesys d iec contactors spring, tesys d iec contactor ring tongue, tesys d iec contactors slipon.

Control circuit voltage average resistance inductance of reference 1 weight uc at 20 c 10 % closed circuit. Aline contactors are mainly used for controlling 3phase motors and for controlling power circuits corresponding to their operating characteristics up to 690 and even vac. Contactors and contactor assemblies digital asset management. Description of 3 pole and 4 pole contactors a9 a300 all aline contactors can be assembled side by side. They offer motor control and overload protection for motors rated up to 100 hp at 480 vac or 125 hp at 600 vac. The current broken ic in category ac3 is equal to the rated operational current ie of the motor. Contactor ratings dline contactors and overload relays are available in 11 contactor ratings for the usa market for inductive motor applications up to 150 fullload amps and resistive loads up to 200 a. Contactors and thermal overload relays conform to the iec standard. Contactors for motor control up to 670kw440 v and power switching up to 2600a. Plentiful products enable easy selection of motor protection.

Tesys contactors 5 for switching 3phase capacitor banks used for power factor correction standard contactors capacitors, together with the circuits to which they are connected, form oscillatory circuits which can, at the moment of switchon, give rise to high transient currents 180 in at high frequencies 1 to 15 khz. Tesys iec contactors and overload relays making highfault shortcircuit current ratings simple the latest development in the tesys family of iec contactors and overload relays is component highfault shortcircuit current ratings sccrs. For contactors lc1d09 and lc1d12 only, replace the digit 3 with a 9. Mcs mini contactors 100k the costefficient and spacesaving system the complete range up to 710 kw contactors overview mcs safety contactors 100sc, 4 to 45 kw mechanically llnked contacts 100sd, 55 to 500kw mirror contacts preassembled, non removal auxiliary contacts, red coloured suva and ul 3rd party certifled. Contactors and protection relays schneider electric. Ac and dc control circuit 3pole contactors with touchsafe terminals for power cabling ac3 category maximum horsepower ratings maximum. M379f distant control of ac relays, contactors and starters. Minia 25 installation contactors rsia with ac control voltage the values shown in the table are valid for rsia installation contactors of onemodule design with contact arrangement 10, 20, 11, 02. Tesys k contactors and reversing contactors environment characteristics conforming to standards iec 60947, nf c 63110, vde 0660, bs 5424 product certifications lcp and lppk06 to k12 ul, csa operating positions vertical axis horizontal axis without derating without derating possible positions for lcpk only. Schneider electric tesys iec contactors tesys k, d, and f. Distant control of ac relays, contactors, and starters. Iec contactors and starters table of contents section 18 tesys iec contactors and starters for more information on lighting, definite purpose dp, and elevator ratings for tesys d and tesys f contactors, refer to catalog 8502ct9901. Selection of contactors for motor control the tables below show the kilowatt ratings for international applications and horsepower ratings for north american applications of contactors for motor control. Sccrs identify the level of fault current that a component or assembly can safely withstand.

Ac dc compatible coil, reversing contactors tesys d green. Minia 25 installation contactors rsia with ac control voltage the values shown in the table are valid for rsia installation contactors of onemodule design with. For requirements according to iec 600771 and iec 600772. To build a complete reversing contactor, order contactors lc1 v160pp separately. Selection guide tesys contactors from 115 to 2750 a applications control of all types of motor for standard or severe duty applications control of resistive, inductive and capacitive circuits.

Gas fflled design offers lower resistance than nonhermetic switches resulting in higher. Selection according to required electrical durability, in category ac3 ue 660690 v control of 3phase asynchronous squirrel cage motors with breaking whilst running. Lc1f400 tesys f contactor3p3 noac3 tesys f contactor 3p3 noac3 tesys d contactors up to 150 a for ac3 75 kw 400 v and 200 a for ac1 applications. Tesys dline contactors and starters general information. This consumption is generated by various types of load. Tesys d contactors for capacitor switching why compensate for reactive energy. Discover schneider electric range of products in contactors and protection. Contactor at load side variable speed drives lmpforum. Characteristics tesys contactors tesys d contactors. Rsi switching devices installation contactors rsi for switching of electrical circuits by application of control voltage on the coil.

1685 901 1357 217 1339 308 1287 680 1173 1308 345 679 1295 123 948 1000 1517 831 1357 695 1405 110 570 567 104 1497 22 1436 580 636 976 649 328 756 27 63 1382 821 549 495